MIRCOM TECHNOLOGIES LIMITED, ADC Series: Autodialer Telephone Access Systems Page 31
SET DOOR TIMER
To change Door-Open Timer (factory default is 10 seconds), scroll through until you reach the feature as shown
below.
[1=Bck] [3=Fwd]
Do you want to edit
The Door-Open-Timer?
[*=Abort] [#=Yes]
Press # to access the feature. The display should appear...
-Program Options-
Door-Open Timer
00 to 99 Sec. _ _
Please enter choice:
Enter the desired door-open period. The next display should appear...
-Program Options-
#=Store, *=Abort
00 to 99 Sec. x x
Please enter choice:
Press # to store or * to abort entry. Press * to exit to PROGRAM MODE menu. To quit, enter *000 while at the
PROGRAM MODE menu to return to NORMAL MODE.
SET ON-LINE TIMER
To change the On-Line period (factory default is 60 sec.), scroll through until you reach the feature as shown below.
[1=Bck] [3=Fwd]
Do you want to edit
On-Line Timer?
[*=Abort] [#=Yes]
Press # to access the feature. The display should appear...
-Program Options-
On-line Timer
00 To 99 Sec. _ _ <== 99 seconds max.
Please enter choice: Note: Set to 00 for 4 min. & 10 sec.
Enter the On-Line period. The next display should appear...
-Program Options-
#=Store, *=Abort
00 To 99 Sec. x x
Please enter choice:
Press # to store or * to abort entry. Press * to exit to the PROGRAM MODE menu. To quit, enter *000 while at the
PROGRAM MODE menu to return to NORMAL MODE.

Table of Contents