EasyManua.ls Logo

Mitsubishi Electric CR800-D Series - Robot (system) Status Variables; Consumption Status (Servo ON Time)

Mitsubishi Electric CR800-D Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Robot (system) status variables 134
M_PMStsBrg: Consumption status (bearing)
[Function]
Returns the consumption status of bearing of the specified axis.
[Format]
Example) <Numeric variable> = M_PMStsBrg(<Axis number>)
[Terminology]
<Numeric variable> Specify the numeric variable to assign.
<Axis number> Specify the joint axis to get the cumulative rotation count. (1 to 6)
When omitted, 1 is used.
[Sample]
1 M1 = M_PMStsBrg(1) 'The consumption status of the bearing of the J1 axis is set in M1.
[Explanation]
(1) Returns the consumption status of the bearing of each joint axis of the robot body (mechanism 1).
0 : The remaining time exceeded the warning occurrence remaining time.
1 : The remaining time is less than the warning occurrence remaining time, exceeded 0 [h].
2 : The remaining time is 0 [h] or less.
(2) This variable is read only.
(3) Returns "-1" when the predictive/preventive maintenance function is disabled.
(4) Returns "0" when a nonexistent axis is specified in <Axis number>.
(5) Returns "0" when the joint axis does not have the target parts.

Table of Contents

Other manuals for Mitsubishi Electric CR800-D Series

Related product manuals