EasyManua.ls Logo

Mitsubishi Electric CR800-D Series - Parameter; Setting Parameters (Abnormality Detection)

Mitsubishi Electric CR800-D Series
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter 172
14.3. Abnormality detection function
14.3.1. Setting parameters
(*1 Attributes in the table, R: Read only, W: Write only, R/W: Read/write)
Parameter
Parameter
name
Number of
elements
Details explanation
Factory
setting
Attribute
*1)
Detection level
(reduction gear
abnormality
detection)
PMWNGDRV
Integer 6
Specify the detection level of the
predictive maintenance function
(reduction gear abnormality detection).
Specify the score which causes a
warning by the predictive maintenance
function for the reduction gear including
the reduction gear of each joint axis.
Setting range: -1 or higher
*-1: When you set -1, detection is
disabled
* This parameter can be written while
the program is in operation.
-1, -1, -1,
-1, -1, -1,
-1, -1
R/W
Detection level
(encoder data
abnormality
detection)
PMWNGEN1
Integer 6
Specify the detection level of the predictive
maintenance function (encoder data
abnormality detection).
Specify the score (encoder data
abnormality) which causes a warning for
the encoder of each joint axis to occur by
the predictive maintenance function.
Setting range: -1 to 100
*-1: When you set -1, detection is
disabled
* This parameter can be written while the
program is in operation.
30, 30,
30, 30,
30, 30,
30, 30
R/W
Detection level
(encoder
communication
abnormality
detection)
PMWNGEN2
Integer 6
Specify the detection level of the
predictive maintenance function (encoder
communication abnormality detection).
Specify the score (encoder
communication abnormality) which
causes a warning for the encoder of each
joint axis to occur by the predictive
maintenance function.
Setting range: -1 to 100
*-1: When you set -1, detection is
disabled
* This parameter can be written while the
program is in operation.
30, 30,
30, 30,
30, 30,
30, 30
R/W
Notification
method of
abnormality
detection
PMRPTSCR
Integer 2
Specify the notification method of the
predictive maintenance function
(abnormality detection).
Specify the behavior of the predictive
maintenance function when the score
exceeded the detection level.
Element 1: Issues warning/does not issue
warning (1/0)
Element 2: Outputs/does not output
dedicated signal (1/0)
0, 0
R/W

Table of Contents

Other manuals for Mitsubishi Electric CR800-D Series

Related product manuals