166
9 CREATING A HARDWARE LOGIC
9.2 Multi Function Counter Block
Output terminal
In the sixth section in the multi function counter block detail window, one output terminal ("Output 0") is arranged by default.
When terminals have been linked to the output terminal, the signals input to the output terminal can be output from the
"Output" terminal in the multi function counter block arranged in the hardware logic outline window.
Output
The following table shows the output of the output terminal.
Variable name Data type Linkable block Valid range Description
Output Bit • Input signal event
detection
• Set/reset
0, 1 Outputs the High/Low states of the "Output 0" terminal
of a multi function counter block in the hardware logic
outline window. This terminal is used for link in the multi
function counter block detail window. Multiple signals
can be input to the terminal. OR processing is
executed for all input signals.