172
10 BLOCK LINK EXAMPLES
10 BLOCK LINK EXAMPLES
Various controls can be performed with the combinations of various blocks. This chapter shows link examples to perform the
following controls.
Control name Description Reference
Coincidence detection Turns on the output of the multi function counter block at coincidence detection. Page 173 Coincidence
Detection
One-shot timer Turns on the output of the multi function counter block for the specified time period.
After the specified time period, the output is turned off until the next event detection.
Page 178 One-shot Timer
Event generation Outputs an external input signal as an event signal. The output signal can be linked
as an event signal of other multi function counter blocks.
Page 182 Event Generation
Cam switch Turns on or off the output when a count value within the upper and lower limit value
range becomes equal to or larger than the setting value of the corresponding steps.
Page 184 Cam Switch
PWM output Outputs a PWM wave with the specified cycle and duty ratio. Page 187 PWM Output
Fixed cycle output Outputs one pulse at every specified cycle. Page 190 Fixed Cycle Output
Latch counter Latches (holds) a count value. Page 193 Latch Counter
Ratio conversion Outputs an input signal multiplied with the set ratio (x/y). Page 196 Ratio Conversion
Pulse measurement Measures the ON width and OFF width of an input pulse. Page 201 Pulse
Measurement