10 BLOCK LINK EXAMPLES
10.5 PWM Output
189
10
Operation
The following shows operation of when the PWM output start signal (input terminal 0) is input and when the PWM output stop
signal (input terminal 1) is input.
No. Description
(1) When a signal is input to the input terminal 0, output of the PWM wave starts.
(2) When a signal is input to the input terminal 1, the output of the PWM wave stops.
(1)
High
Low
7ms 3ms
High
Low
High
Low
(2)
3ms 7ms
Cycle time ON time
Output terminal
Input terminal 1
Input terminal 0
Controlled by the flexible high-speed I/O control module