Chapter 8
114
Flexi Line
Teaching using Setting and Monitoring Tool
In the Flexi Line view in Setting and Monitoring Tool there is a Teach button on the
toolbar.
Click the Teach button during commissioning when all stations are switched on and
in the Teach required state. The topology of the system is then checked and
confirmed and the Flexi Line system is started.
Teaching using a pushbutton
If it is necessary to be able to remove, add or replace individual stations during
operation, then you can also run the Teach function using a pushbutton.
How to configure the Teach function using a pushbutton:
Connect a Teach button to the inputs of the station in the Flexi Line system that
shall be able to activate the Teach function. The Teach button can be e.g. a dual
channel key operated switch.
In the logic editor for this station, use a Restart function block to connect the
Teach button input to this station’s Teaching output as shown in Figure
85.
If the Teach button is pressed, the Teaching output will become High for one logic
cycle. The rising edge (Low to High) on the Teaching output triggers the Teach
function.
Figure 85:
Configuration of the Teach
function in the logic editor