Operating mode “Add. heat only”
Intheeventofmalfunctionsthatcausealowindoortemperature,
you can normally activate “Add. heat only” in indoor unit, which
means that heating only occurs with the immersion heater.
Activate the mode by holding in the operating mode button
for 7 seconds.
Notethatthisisonlyatemporarysolution,asheatingwiththe
immersionheaterdoesnotmakeanysavings.
Emergency mode
Emergencymodeisactivatedbysettingtheswitchto“ ”.
Itisusedwhenthecontrolsystemandtherebyoperatingmode
“Add.heatonly”donotfunctionas they should. Emergency
modeisactivatedbysettingswitch(SF1)to“
”.
Thefollowingappliesinemergencymode:
■ Thefrontpanelisnotlitandthecontrolcomputerinindoor
unit is not connected.
■ Outdoor unit is off andonly the circulation pump and
immersion heater in indoor unit are active.
■ Anelectricalstep of4 kWis connected.The immersion
heater is controlled by a separate thermostat (BT30).
■ Theautomaticheatingcontrolsystemisnotoperational,so
manual shunt operation is required. Call installer.
The phenomena mentioned below are not malfunction.
The air conditioning system
sounds as if water is
draining from it.
Soundsofrustlingorgurglingmaybeheardwhentheoperationisstarted,whenthecompressoris
activated/deactivated during operation, or when the operation is stopped. These are the sounds of the
refrigerantowingthroughthesystem.
Soundsofrustlingor
gurgling may be heard from
a stopped indoor unit.
These sounds can be heard when the air conditioning system is performing automatic control.
The air conditioning system
cannot start operating again
immediately after stopping.
Outdoorunitdoesn’trestartduringtherst3minutesafterstoppingoperation.Thisisbecauseacircuit
for protecting the compressor is activated (the fan is operating during this period).
The outdoor unit discharges
water or steam during
heating operation.
Waterorsteamisdischargeduringdefrostingoperationwhichremovesfrostbuiltuponthesurfaceof
the heat exchanger in the outdoor unit in heating mode.
The outdoor unit fan is not
running even when the
system is in operation.
Thefanspeedisautomaticallycontrolledaccordingtotheoutdoorairtemperature.Itmaybestoppedin
high outdoor air temperature in case of heating, and in low outdoor air temperature in case of cooling.
Also, the fan is stopped during defrosting operation.
REQUESTS
The fan will suddenly begin to operate even if it is stopped. Do not insert finger and/or stick.
Hissing sounds are heard
when the operation is
stopped or during defrost
operation.
These sounds are generated when the refrigerant valve inside the air conditioning system is activated.
Dealing with comfort disruption