Control
-
97
-
'10 • HM-T-149
4.0 [N] Outdoor temp.
Menu 4.1 [N] Outdoor avg. temp.
This menu shows the average outdoor temperature according
to the set value in Menu 4.2 (factory setting: 24h).
Menu 4.2 [U] Outdoor filter time
Here you select during how long the average temperature in
Menu 4.1 is calculated.
Setting range: 1 min, 10 min, 1h, 2h, 4h, 6h, 12h, 24h
Default value: 24h
Menu 4.3 [U] Outdoor avg. 1min.
Shows the average outdoor temperature over the last minute.
Menu 4.4 [N] Return
Return to Menu 4.0.
5.0 [N] Heat pump
Menu 5.1 [N] Number of starts
The accumulated number of starts with the compressor in
outdoor unit is shown here.
Menu 5.2 [N] Run time compressor
The accumulated time that the compressor has been used in
outdoor unit is shown here.
Menu 5.3 [U] Time to start
Time until the compressor start in outdoor unit is shown in this
menu.
Menu 5.4 [U] Outdoor temp. Tho-A
This menu shows the outdoor air temperature that the heat
pump measures.
Menu 5.5 [U] Heat Ex Tho-R1
This menu shows the evaporator temperature in the heat pump
at sensor Tho-R1.
Menu 5.6 [U] Heat Ex Tho-R2
This menu shows the evaporator temperature in the heat pump
at sensor Tho-R2.
Menu 5.7 [U] Suction temp. Tho-S
This menu shows the suction gas temperature in the heat pump.
Menu 5.8 [U] Hot gas Tho-D
This menu shows the hotgas temperature in the heat pump.
Menu 5.9 [U] Liquid line temp.
This menu shows the liquid line temperature in the heat pump.
Menu 5.10 [U] Condensor out / max
Shows the current and max. allowed temperature after the
condenser.
Menu 5.11 [U] HP
The current high pressure and corresponding temperature
during heating are shown here. During cooling, the actual low
pressure and corresponding temperature are shown.
Menu 5.12 [U] LP LPT
The current low pressure is shown here.
Menu 5.13 [U] Fan speed
The fan speed is shown here.
Menu 5.14.0 [U] CompFreq act/set
The actual and set point value for the compressor frequency
are shown here.
Menu 5.14.1 [U] OU current CT
The present phase current to outdoor unit is shown here.
Menu 5.14.2 [U] Inverter temp Tho-IP
The current inverter temperature is shown here.
Menu 5.14.3 [U] Return
Return to Menu 5.14.0.
Control