'10 • HM-T-149
Technical data
Installation requirements
Installation requirements
HMA100V, HMA100VM HMS140V
FDCW71VNX
FDCW100VNX FDCW140VNX
Max pressure, climate system 0.25 MPa (2.5 Bar)
Max temperature, climate system 65
℃
Max temperature in indoor unit 65
℃
Max temperature from external heat source 65
℃
Max supply temperature with compressor at outdoor temp. -15
℃
58
℃
Min supply temp. cooling 7
℃
18
℃
Max supply temp. cooling 25
℃
Min volume, climate system without underoor cooling application
35 50 75
Min volume, climate system with underoor cooling application
70 100 150
Max ow, climate system 0.38
l
/s 0.57
l
/s 0.79
l
/s
Min ow, climate system 0.19
l
/s 0.24
l
/s 0.40
l
/s
Nominal system ow heating (
△
T=5K) 0.38
l
/s (8kW,7/45
℃
)
0.43
l
/s (9kW,7/45
℃
)
0.79
l
/s (16.5
k
W,7/45℃)
Nominal system ow cooling (
△
T=5K)
0.34
l
/s (7.1
k
W,35/7
℃
)
0.38
l
/s (8
k
W,35/7℃)
0.79
l
/s (16.5
k
W,35/18℃)
External circulation pump must be used when the pressure drop in the system is greater than the available external pressure. In such
case, a bypass line with non-return valve must be installed.
Use an overflow valve if system flow cannot be guaranteed.