9
-
'10 HM-T-149
Technical data
Installation requirements
Installation requirements
HMA100V, HMA100VM HMS140V
FDCW71VNX
FDCW100VNX FDCW140VNX
Max pressure, climate system 0.25 MPa (2.5 Bar)
Max temperature, climate system 65
Max temperature in indoor unit 65
Max temperature from external heat source 65
Max supply temperature with compressor at outdoor temp. -15
58
Min supply temp. cooling 7
18
Max supply temp. cooling 25
Min volume, climate system without underoor cooling application
35 50 75
Min volume, climate system with underoor cooling application
70 100 150
Max ow, climate system 0.38
l
/s 0.57
l
/s 0.79
l
/s
Min ow, climate system 0.19
l
/s 0.24
l
/s 0.40
l
/s
Nominal system ow heating (
T=5K) 0.38
l
/s (8kW,7/45
)
0.43
l
/s (9kW,7/45
)
0.79
l
/s (16.5
k
W,7/45℃)
Nominal system ow cooling (
T=5K)
0.34
l
/s (7.1
k
W,35/7
)
0.38
l
/s (8
k
W,35/7℃)
0.79
l
/s (16.5
k
W,35/18℃)
External circulation pump must be used when the pressure drop in the system is greater than the available external pressure. In such
case, a bypass line with non-return valve must be installed.
Use an overflow valve if system flow cannot be guaranteed.