Setting Parameters
01/02 AWB8230-1415GB
150
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
A097 Acceleration
characteristic
00 Linear acceleration of the motor at the first and second time
ramps
00
01 S-curve characteristic for acceleration of the motor at the
first and second time ramps
02 U-curve characteristic for acceleration of the motor at the
first and second time ramps
03 Inverted U-curve characteristic for acceleration of the motor
at the first and second time ramps
A098 Deceleration
characteristic
00 Linear deceleration of the motor at the first and second time
ramps
00
01 S-curve characteristic for deceleration of the motor at the
first and second time ramps
02 U-curve characteristic for deceleration of the motor at the
first and second time ramps
03 Inverted U-curve characteristic for deceleration of the motor
at the first and second time ramps
A131 Curvature of
acceleration
characteristic
j 01 Smallest curvature of the acceleration ramp 02
...
10 Largest curvature of the acceleration ramp
A132 Curvature of
deceleration
characteristic
j 01 Smallest curvature of the deceleration ramp 02
...
10 Largest curvature of the deceleration ramp