Setting Parameters
01/02 AWB8230-1415GB
162
Other functions
Inhibit direction of rotation
Under PNU b035, you can specify whether clockwise or anticlock-
wise motor operation is permitted.
Starting behaviour
With the two parameters PNU b036 and b082, you can specify the
voltage ramp and the frequency for starting the motor.
Voltage ramp
If the overcurrent trip is triggered at an increased starting
frequency, you can reduce the starting current and the torque with
PNU b036.
Starting frequency
Under PNU b082, you can set the frequency at which the motor is
to start.
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
b035 Inhibit direc-
tion
– – 00 Motor can run in both directions 00
01 Motor can only run clockwise
02 Motor can only run anticlockwise
Figure 167: Function chart for voltage ramp reduction
f
o
: Output frequency
V
2
:Output voltage
U
2
FWD
PNU b036 =
PNU b082
00 01 06
f
o
Figure 168: Function chart for starting frequency
f
o
: Output frequency
V
2
:Output voltage
U
2
FWD
PNU b036
PNU b082
f
o
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
b036 Voltage ramp
to starting
frequency
– j 00 Start without voltage reduction. 06
01 Minimum voltage reduction, approx. 6 ms
...
06 Maximum voltage reduction, approx. 36 ms
b082 Increased star-
ting frequency
– j 0.1 to 9.99 Hz The motor starts with this frequency. 0.5
For Moeller Electric Sales and Support call KMparts.com (866) 595-9616