Ambient conditions
Ambient temperature 10 to +50 °C
From about +40 to +50 °C, the pulse frequency should be reduced to 2 kHz. The output current should be
less than 80 % of the rated current in this case.
Temperature/humidity during storage
25 to 70 °C (for short periods only, e.g. during transport)
20 to 90 % relative humidity (non condensing)
Permissible vibration
Maximum 5.9 m/s
2
(= 0.6 g) at 10 to 55 Hz
Installation height and location
Maximum 1000 m above sea level in a housing or control panel (IP54 or similar)
Optional accessories
Remote operating unit: DEX-KEY-10
Choke to improve the power factor
DE6-LZ...-V4 RFI filter
Expansion modules
Encoder module: DE6-IOM-ENC
PROFIBUS-DP module: DE6-NET-DP
DV6-340-...
075 1K5 2K2 4K0 5K5 7K5 11K 15K 18K5
DV6-340-... 22K 30K 37K 45K 55K 75K 90K 110K 132K
Protection class accor-
ding to EN 60529
IP20
Overvoltage category
III
Maximum permissible effective motor
power in kW, details for four pole three-
phase current asynchronous motors
22.0 30.0 37.0 45.0 55.0 75.0 90.0 110 132
Maximum permissible
apparent motor power
in kVA at
400 V
33.2 40.1 51.9 62.3 76.2 103.2 121.9 150.3 180.1
480 V
39.9 48.2 62.3 74.8 91.4 123.8 146.3 180.4 216.1
Primary side: Number of phases
Three-phase
Primary side: Rated voltage
342 V ~ 0 % to 528 V ~ + 0 %, 47 to 63 Hz
Secondary side: Rated voltage Three-phase 380 to 480 V ~
Corresponding to the primary side rated voltage
If the primary voltage drops, the secondary voltage also drops.
Primary side: Rated current in A
53.0 63.0 83.0 99.0 121 164 194 239 286
Secondary side: Rated current in A 48.0 58.0 75.0 90.0 110 149 176 217 260
Secondary side: Frequency range
0.1 to 400 Hz
With motors which are operated at rated frequencies above 50/60 Hz, the maximum possible motor speed
should be observed.
Frequency error limits (at 25 °C g10 °C)
Digital setpoint value: g0.01 % of the maximum frequency
Analog setpoint value: g0.2 % of the maximum frequency
Frequency resolution
Digital setpoint value: 0.1 Hz
Analog setpoint value: Maximum frequency/1000
Voltage/frequency characteristic
Constant torque
Reduced torque
Increased (SLV-controlled) torque
Vector-controlled torque (only with optional DE6-IOM-ENC module)
User-programmable V/f characteristic
Permissible overcurrent
150 % for 60 s, 200 % for 0.5 s (once every ten minutes)
Acceleration/deceleration time
0.01 to 3600 s with linear and nonlinear characteristic (applies also for second and third acceleration/
deceleration time)