4 - 14 ET1 Enterprise Tablet Integrator Guide
2 Check Digits - bar code contains two check digits.
Report Check DIgit - Transmit Code 11 data with or without the check digit. A check in the checkbox
indicates to send Code 11 data with check digit (default - disabled).
Webcode
Webcode Subtype - Enables the decoding of the GT Webcode subtype. A check in the checkbox
indicates that the option is enabled (default - disabled).
Matrix 2 of 5
Length1 - Use to set decode lengths (default - 0). See Decode Lengths on page 4-14 for more
information.
Length2 - Use to set decode lengths (default - 0). See Decode Lengths on page 4-14 for more
information.
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the
checkbox indicates that redundancy is enabled (default - disabled).
Report Check Digit - Transmit Matrix 2 of 5 data with or without the check digit. A check in the
checkbox indicates to send Matrix 2 of 5 data with check digit (default - enabled).
Verify Check Digit - Enable this feature to check the integrity of all Matrix 2 of 5 symbols to verify that
the data complies with a specified check digit algorithm (default - enabled).
UPCE1
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of
the data. Enables or disables this option. A check in the checkbox indicates that the option is enabled
(default - disabled).
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. There are three options for transmitting a UPCE1 preamble:
Preamble Sys Char - Transmit System Character only.
Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA).
Preamble None - Transmit no preamble (default).
Select the appropriate option to match the host system.
Convert UPCE1 To UPCA - Enable this to convert UPCE1 decoded data to UPC-A format before
transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming
selections. Disable this to transmit UPCE1 decoded data as UPCE1 data, without conversion (default
- disabled).
Decode Lengths
The allowable decode lengths are specified by options Length1 and Length2 as follows:
Variable length: Decode symbols containing any number of characters.
Set both Length1 and Length2 to 0.
Range: Decode a symbol with a specific length range (from a to b, including a and b).
Set Length1 to a and set Length2 to b.
Two Discrete Lengths: Decode only symbols containing either of two selected lengths.
Set either Length1 or Length2 to the specific lengths.
One Discrete Length: Decode only symbols containing a specific length.
Set both Length1 and Length2 to the specific length.