MiiNePort E2/E3 Introduction to SCM (Serial Command Mode) Command Set
A-6
Location
Command code: ML
Command parameters: N/A
Reply parameters: MiiNePort’s SNMP Location.
?GML
System requests SNMP location for this MiiNePort.
!GML0s_location
MiiNePort reports SNMP location as s_location’.
Enable/Disable Accessible IP List
Command code: AS
Command parameters: N/A
Reply parameters: Enable (1) or Disable (0) MiiNePort’s accessible IP list.
?GAS System requests Enable/Disable accessible IP list for this MiiNePort.
!GAS01
MiiNePort reports accessible IP list as Enable’.
Accessible IP List
Command code: AI
Command parameters: The index of accessible IP list (from 1 to 16)
Reply parameters: Return format Mode;IP;Netmask in the accessible IP list. If mode equals to 1, it is active,
otherwise it is inactive.
?GAI1
System requests first accessible IP list for this MiiNePort.
!GAI01;192.168.1.2;255.255.25
5.0
MiiNePort reports first accessible IP list as Active, IP address as
192.167.1.2, and Netmask as 255.255.255.0’.
Auto IP Report
Command code: NR
Command parameters: N/A
Reply parameters: MiiNePort’s auto IP report setting.
?GNR
System requests auto IP report for this MiiNePort.
!GNR0192.168.1.250:4000;50
MiiNePort reports Auto IP report server as 192.168.1.250and port as
4000, and report period as 50’.
Port alias
Command code: SA
Command parameters: Port index.
Reply parameters: MiiNePort’s Port alias.
?GSA1
System requests port 1 alias for this MiiNePort.
!GSA0port1
MiiNePort reports Port alias as port1’.

Table of Contents