4. On the GFCI outlet, note the status light indicator:
l
Red device needs attention
l
Green power on and working
l
Off no power as the GFCI has tripped
5. To test a GFCI outlet, press the test button.
The unit shuts off the power to the connected device.
6. To reset a GFCI outlet, press the reset button.
The unit resets the circuit and makes the outlet active again.
3.5 Connecting cam-lock cables
Enable a secure and efficient electrical power transfer by connecting your load to the
unit with cam-lock cables.
To connect cam-lock cables, follow these steps:
1. Connect your ground.
2. At the back of the unit, locate the bottom right panel door.
For more information, see
Cam-lock
connections
on page 30
3. If needed, unlock the panel door with the supplied keys, and then pull the latch to
open the door.
4. Open the caps of the cam-lock receptacles.
5. Insert your cam-lock plugs, and rotate your cam-lock plugs 180° clockwise to
fully secure them.
Make sure you have identified the cables and fitted the correct
NEUTRAL
and
GROUND
cables.
Your cam-lock connections are now in place and ready to receive power from the unit.
3.6 Connecting twist-lock cables
Enable a secure and efficient electrical power transfer by connecting your load to the
unit with twist-lock cables.