© Munters AB, 2020 54
7.2 Temperature Sensors
•
Defining the Temperature Sensors
•
Mapping the Temperature Sensors
•
Enabling a Weather Station
7.2.1 D
EFINING THE
T
EMPERATURE
S
ENSORS
Define up to 12 analog input ports as temperature sensors (and one port as an outside
temperature sensor) (refer to Mapping Devices).
•
Define:
o
Offset: This is an optional correction for the temperature sensor. Range: -10⁰ C to +10⁰ C
o
Enabled: enable/disable the sensor.
•
The temperature reading shows the measured temperature, including the offset.
7.2.2 M
APPING THE
T
EMPERATURE
S
ENSORS
Calculating the temperature data, TRIO takes the following into consideration:
•
Tunnel temperature: Select a sensor or a group of sensors to determine the tunnel temperature
readings or select if the tunnel run according to the average temperature reading.
•
Average temperature: Data from multiple sensors can be averaged. If a sensor fails, the
sensor's data is removed from any calculations.
•
Device temperature: A sensor (or sensors) can be mapped to a specific device.