70
System data: Each line of the system data has 16 bytes of individual
system setup ‘flags’.
Consist data: Each line of the Consist data holds 8 locomotive addresses.
Locations F500-F5FF hold lead loco addresses. The first two bytes are consist address 0
(not used) addresses are in DCC format (bits 6,7 of high byte set if long address).
Locations F600-F6FF hold rear loco addresses. The first two bytes are consist address 0
(not used) addresses are in DCC format (bits 6,7 of high byte set if long address) .
Locations F700-FBFF hold mid consist loco addresses. The first 8 bytes are up to 4 locos
in consist address 0 (not used) addresses are in DCC format (bits 6,7 of high byte set if
long address).
HIGHEST CAB TO PROGRAM ON MAIN
This sets the highest Cab address that will be able to access programming on the Main.
Cabs above this setting will skip the PROGRAM ON MAIN menu selection. 00 = all Cabs
have access. This and the following command station setup parameters are useful for
clubs that have a lot of members but want to limit which of those members can access
various system options during an operating session. Press ENTER to skip setting this
parameter.
HIGHEST CAB TO ASSIGN LOCO
This sets the highest Cab address that will be able to access the Assign Loco to Cab
menu. Cabs above this setting will skip the ASSIGN LOCO CAB menu selection. 00 =
all Cabs have access. Press ENTER to skip setting this parameter.
HIGHEST CAB TO SET CLOCK
This sets the highest Cab address that will be able to access the Set Clock menu. Cabs
above this setting will skip the SET SYSTEM CLOCK menu selection. 00 = all Cabs have
access. Press ENTER to skip setting this parameter.
HIGHEST CAB TO USE PROGRAM TRACK
This sets the highest Cab address that will be able to access the programming Track.
Cabs above this setting will skip the USE PROGRAM TRK menu selection. 00 = all Cabs.
Press ENTER to skip setting this parameter.
HIGHEST CAB TO SET COMMAND STATION
This sets the highest Cab address that will be able to Set Up the Command Station.
Cabs above this setting will skip the SET CMD STATION menu selection. 00 = all Cabs.
Press ENTER to skip setting this parameter.
HIGHEST CAB TO SET ITSELF
This sets the highest Cab address that will be able to access the Set Cab Parameters
menu. Cabs above this setting will skip the SET CAB PARAMS menu selection. 00 = all
Cabs have access. Press ENTER to skip setting this parameter.
HIGHEST CAB TO PROGRAM ACCESSORIES
This sets the highest Cab address that will be able to program Accessories while they
are attached to the main track. Cabs above this setting will skip the PROG
ACCESSORIES menu selection. 00 = all Cabs. Press ENTER to skip setting this
parameter.
HIGHEST CAB TO PROGRAM MACROS
This sets the highest Cab address that will be able to program macros. Cabs above this
setting will skip the PROGRAM MACROS menu selection. 00 = all Cabs. Press ENTER to
skip setting this parameter.
HIGHEST CAB TO PROGRAM SIGNALS
This sets the highest Cab address that will be able to program signal decoders while
they are attached to the main track. Cabs above this setting will skip the PROG