8-17
Error
code
Error message Recommended Action
0B8D Could not redirect the console - BMC Busy -
0B8E Could not redirect the console - BMC Error -
0B8F Could not redirect the console - BMC Parameter Error -
0B90 BMC Platform Information Area corrupted.
0B91 BMC update firmware corrupted.
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your service
representative.
0B92 Internal Use Area of BMC FRU corrupted.
All the commands and functions other than the FRU
command and the EMP function can be used. This is not a
fatal error. Turn off the power once and then on again to
restart the server. If the error cannot be corrected, contact
your service representative.
0B93 BMC SDR Repository empty.
Turn off the power once and then on again to restart the
server. If the error cannot be corrected, contact your service
representative.
0B94 IPMB signal lines do not respond.
All the functions other than the function of accessing to
SMC through IPMB can be used. This is not a fatal error.
Turn off the power once and then on again to restart the
server. If the error cannot be corrected, contact your service
representative.
0B95 BMC FRU device failure.
All the commands and functions other than the FRU
command and the EMP function can be used. This is not a
fatal error. Turn off the power once and then on again to
restart the server. If the error cannot be corrected, contact
your service representative.
0B96 BMC SDR Repository failure.
0B97 BMC SEL device failure.
0B98 BMC RAM test error.
0B99 BMC Fatal hardware error.
0B9A BMC not responding.
0B9B Private I2C bus not responding.
0B9C BMC internal exception.
0B9D BMC A/D timeout error.
0B9E SDR repository corrupt.
0B9F SEL corrupt.
Turn off the power once and then on again to start the
server. If the error cannot be corrected, contact your service
representative.
0BB0 SMBIOS - SROM data read error.
0BB1 SMBIOS - SROM data checksum bad.
Contact your service representative.
0BC0 POST detected startup failure of 1st Processor.
0BC1 POST detected startup failure of 2nd Processor.
0BC2 POST detected startup failure of 3rd Processor.
0BC3 POST detected startup failure of 4th Processor.
Contact your service representative to replace the
processor.
8120 Unsupported DIMM detected in DIMM group #1.
8121 Unsupported DIMM detected in DIMM group #2.
8122 Unsupported DIMM detected in DIMM group #3.
8123 Unsupported DIMM detected in DIMM group #4.
8124 Unsupported DIMM detected in DIMM group #5.
8125 Unsupported DIMM detected in DIMM group #6.
8126 Unsupported DIMM detected in DIMM group #7.
8127 Unsupported DIMM detected in DIMM group #8.
Contact your service representative to replace the two
DIMMs in the relevant group.
8130 Mismatch DIMM Type detected in DIMM group #1.
8131 Mismatch DIMM Type detected in DIMM group #2.
8132 Mismatch DIMM Type detected in DIMM group #3.
8133 Mismatch DIMM Type detected in DIMM group #4.
8134 Mismatch DIMM Type detected in DIMM group #5.
8135 Mismatch DIMM Type detected in DIMM group #6.
8136 Mismatch DIMM Type detected in DIMM group #7.
8137 Mismatch DIMM Type detected in DIMM group #8.
See the labels put on the DIMMs to make sure that the
DIMMs of the same type are installed in groups. If DIMMs
of different types are installed in one or more groups,
contact the service representative to replace DIMMs
properly.