EasyManua.ls Logo

NEC Express5800 140Rd-4 - Page 220

NEC Express5800 140Rd-4
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-18
Error
code
Error message Recommended Action
8140 DIMM group #1 with error is enabled.
8141 DIMM group #2 with error is enabled.
8142 DIMM group #3 with error is enabled.
8143 DIMM group #4 with error is enabled.
8144 DIMM group #5 with error is enabled.
8145 DIMM group #6 with error is enabled.
8146 DIMM group #7 with error is enabled.
8147 DIMM group #8 with error is enabled.
Contact your service representative to replace the two
DIMMs in the relevant group.
8150 NVRAM Cleared By Jumper.
8151 Password Cleared By Jumper.
Turn off the power. Then recover the jumper setting to the
original setting.
8160 Mismatch Processor Speed detected on Processor 1.
8161 Mismatch Processor Speed detected on Processor 2.
8162 Mismatch Processor Speed detected on Processor 3.
8163 Mismatch Processor Speed detected on Processor 4.
8170 Processor 1 not operating at intended frequency
8171 Processor 2 not operating at intended frequency
8172 Processor 3 not operating at intended frequency
8173 Processor 4 not operating at intended frequency
817F All processors not operating at intended frequency
Check the frequency of the processor. If it is unknown,
contact your service representative.
8200 Online Spare Memory was not ready.
DIMM type mismatch is detected when the online spare
memory feature is enabled.
Contact your service representative.
8201 Mirroring Memory was not ready.
DIMM type mismatch is detected or unnecessary
installation in group #2 is detected when the memory
mirroring feature is enabled. Check the DIMM type or
installation. If the error cannot be corrected, contact your
service representative.
8202 Memory RAID was not ready.
Check if capacity, type, and installation status of all DIMMs
are correct.
8300 Secondary BIOS is corrupted. Contact your service representative.
Other POST Errors
The following message does not appear on the screen, however, it is recorded in the system event log.
Error code Description Recommended Action
8301
A BIOS Checksum error was detected in the
early stage of BIOS boot-up (Bootblock). The
control was transferred to the secondary BIOS.
(See Chapter 2 "Recovering BIOS Data".)
Contact your service
representative.

Table of Contents