“Confidential, Do Not Duplicate without written authorization from NEC.”
5-16
SERVICE MODE
Bulb Alignment
This function is used to display the Lamp Brightness value read out by the optical sensor.
This value has no correlation to the projector.
This function ensures easy adjustments when the lamp bulb alignment is adjusted.
Example of display
Installation
Bulb Alignment
Peakhold 4095
< Average 2400 >
First line : Indication of "Installation"
Second line : Indication of "Bulb Alignment"
Third line : Indication of "Peak Hold" value
Fourth line : Indication of "Average" value
Peak hold : Maximum value read out by the optical sensor is displayed.
(This value is cleared when ENTER is pressed.)
Average : A mean value of the data obtained by the optical sensor is displayed.
Memory
The present status of Lamp and Lens is overwritten in Entries of the selected lamp and lens memories.
1 Lamp
The present status of Lamp output is overwritten in the selected Lamp Memory Entry.
Example of display
Memory
Lmap
(*)
< Memory Name >
First line : Indication of "Memory"
Second line : Indication of "Lamp"
Third line : Indication of current setup
Fourth line : Indication of Memory Name registered