– 344 – NWA-008841-001 Rev.5.0
90ch3003.fm
The figure in the SWITCH NAME column and the position of in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
Continued on next page
SW11 (Dip SW)
1
For normal operation
OFF Not used
2
NOTE 3
ON
Source clock signal from network is
sent to the PLO of MP card according
to the switch setting of SW11-3.
OFF
Source clock signal from network is not
sent to the PLO of MP card.
3
NOTE 3
ON
Output clock signals to the PLO0 of MP
card.
OFF
Output clock signals to the PLO1 of MP
card.
4
ON AP No. 04-15
OFF AP No. 20-31
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION CHECK
1
2
3
4
ON
ON
PN-2BRTC (BRT)