EasyManua.ls Logo

NEC NEAX 2000 IPS - Page 72

NEC NEAX 2000 IPS
619 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 1 GENERAL INFORMATION
– 56 – NWA-008841-001 Rev.5.0
90ch1001.fm
Continued on next page
CARD NAME MOUNTING CONDITIONS
PN-32IPLA
PN-32IPLA-A
PN-16VCTA
PN-16VCTA-A
[For Series 3300 or later]
PN-32IPLA/PN-32IPLA-A (IP-PAD) card is to be mounted in the
LT01 and/or LT05 slots of PIM0-7.
In the following cases, other L/T card and/or AP card can be
mounted in the adjoining left side slot of IP-PAD card.
In the following cases, according as number of channels, do not
mount any other L/T cards in the LT08-LT11 slots when you mount
the IP-PAD card in the LT05 slot.
NOTE: For Backup CPU system, do not mount in the LT08-LT10
slots.
IP-PAD
CARD
16VCT
CARD
×: ALLOWED -: NOT ALLOWED
OTHER LINE/TRUNK
CARDS
APPLICATION PROCESSOR
CARDS
CHANNEL
NO.
SLOT
NO.
LT02 LT03 LT06 LT07 LT02 LT03 LT06 LT07
16 CH
LT01
NONE
×× ××
LT05 ×× ××
24 CH
LT01
NONE
- ×××
LT05 - ×××
32 CH
LT01
NONE
-- ××
LT05 - - ××
16 CH
LT01
ONE
CARD
- × - ×
LT05 - × - ×
24/32
CH
LT01
TWO
CARDS
-- --
LT05 -- --
IP-PAD
CARD
×: ALLOWED -: NOT ALLOWED
OTHER LINE/TRUNK
CARDS
APPLICATION PROCESSOR
CARDS
CHANNEL
NO.
SLOT
NO.
LT08 LT09 LT10
LT11
NOTE
LT08 LT09 LT10
LT11
NOTE
16 CH
LT0 5
--××××××
24 CH ---×××××
32 CH ----××××
JULY/1/2006
MOUNTING CONDITIONS OF CIRCUIT CARDS

Table of Contents

Other manuals for NEC NEAX 2000 IPS

Related product manuals