Issue 1.0 UNIVERGE SV8100
2 - 984 Station Message Detail Recording
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
10-12-01 CD-CP00-AU Network Setup – IP
Address
Assign the IP Address. 0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~
191.254.255.254
192.0.0.1 ~
223.255.255.254
(default = 192.168.0.10)
3
10-20-01 LAN Setup for External Equipment
– TCP Port
Define the TCP port (0~65535)
when communicating to the SMDR
(type 5).
0~65535
default:
External Device 1 (CTI
Server) = 0
External Device 2 (ACD
MIS) = 4000
External Device 5 (SMDR
Output) = 0
External Device 6 (DIM
Output) = 0
External Device 11 (O&M
Server) = 8010
3
10-20-03 LAN Setup for External Equipment
– Keep Alive Time
Use to define the keep alive time for
communicating to external
equipment.
1~255 (seconds)
(default = 30)
3
14-01-06 Basic Trunk Data Setup – SMDR
Printout
Use this option to have the system
include(1) or exclude (0) the trunk
you are programming from the
SMDR printout. Refer to Program
35-01 and 35-02 for SMDR printout
options.
0 = No Print Out
1 = Prints Out
(default = 1)
3
14-04-01 Behind PBX Setup For ANI/DNIS, the following
additional setting is recommended:
Behind PBX = 0 (Stand Alone).
0 = Stand Alone (Trunk)
1 = Behind PBX (PBX)
2 = Not Used
3 = CTX assume 9
(default = 0)
3
15-01-03 Basic Extension Data Setup –
SMDR Printout
For each extension, enter 1 if
extension calls should appear on
SMDR report. Enter 0 if extension
calls should not appear on SMDR
report.
0 = Do not print on SMDR
report
1 = Include on SMDR
report
(default = 1)
3
20-07-18 Class of Service Options
(Administrator Level) – SMDR
Printout Accumulated Extension
Data
Used to determine if Accumulated
Extension Data is included in the
SMDR report for each COS.
0 = Off
1 = On
(default = 0 for
COS 1~14)
(default = 1 for
COS 15)
3