Loading...
UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 607
20-13-06 Class of Service Options
(Supplementary Service) –
Automatic Off-Hook Signaling
(Automatic Override)
Allows a busy extension ability to
Manually (0) or Automatically (1)
receive Off-Hook Signals.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
80-01-01
(28)
Service Tone Setup – Tone 28
(Speaker Monitor Tone)
This tone changes the tone the
originator of an ICM call hears. (The
tone cannot be changed for what is
heard by the user when receiving
an ICM call.)
0~255 (default 0 = until
On-Hook)
Refer to Table 2-14
Service Tone Setup,
Program 80-01-01 on
page 2-555 (Service
Tone #28).
3
80-01-02 Service Tone Setup – Basic Tone
Number
Use to define up to 64 Service
Tones. Each service tone is defined
by the combination of 32 Basic
Tones.
1~33
(0 = No Tone)
(33=Default Time Slot)
Refer to Table 2-15
Service Tone Setup,
Program 80-01-02 on
page 2-558.
3
82-01-01 Incoming Ring Tone –
Frequency 1
Customize the Intercom ring tone. 1 = 520Hz
2 = 540Hz
3 = 660Hz
4 = 760Hz
5 = 1100Hz
6 = 1400Hz
7 = 2000Hz
Default:
Refer to Table 2-17
Incoming Ringing Tone
on page 2-607
3
Table 2-17 Incoming Ringing Tone
Incoming Ring Tone
Number
Tone
Type Frequency 1 Frequency 2 Modulation
Pattern 1
(Trunk Incoming)
High
Mid
Low
1100
660
520
1400
760
660
16Hz Modulation
16Hz Modulation
16Hz Modulation
Pattern 2
(Trunk Incoming)
High
Mid
Low
1100
660
520
1400
760
660
8Hz Modulation
8Hz Modulation
8Hz Modulation
Pattern 3
(Trunk Incoming)
High
Mid
Low
2000
1400
1100
760
660
540
16Hz Modulation
16Hz Modulation
16Hz Modulation
Pattern 4
(Trunk Incoming)
High
Mid
Low
2000
1400
1100
760
660
540
8Hz Modulation
8Hz Modulation
8Hz Modulation
Intercom Incoming Pattern
High
Mid
Low
1100
660
520
1400
760
660
8Hz Modulation
8Hz Modulation
8Hz Modulation
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents