UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 27
Alarm Reports
Description
The UNIVERGE SV8100 system logs various errors and reports information about the operation that can
be used to determine the cause of a problem. The system can indicate several errors on the multiline
telephone display, output to a USB stick on the CD-CP00-AU, or be downloaded in PCPro. The report
data can also be sent via e-mail.
Alarm Report
The Alarm Reports indicate:
System start-up/upgrade date and time
Blade communication error with date and time and the restoration date and time
Date and time a blade was removed from the system
Date and time an extension was disconnected from the system
Date and time of any system data change
Table 2-1 Sample Alarm Report
<< Alarm Report05/16/2006 14:30 PAGE 001
LVL NO STAT DATE TIME ITEM UNIT SLT PRT PARAMETER
MIN 0002 REC 05/16/06 14:21 PKG Installation PRT 02 00
MAJ 0010 ERR 05/16/06 14:21 ISDN Link PRT 02 12
MAJ 0010 REC 05/16/06 14:21 ISDN Link PRT 02 12
MIN 0002 ERR 05/16/06 14:33 PKG Installation PRT 02 00
MIN 0002 ERR 05/16/06 14:33 PKG Installation ESI 05 00
MIN 0002 ERR 05/16/06 14:33 PKG Installation SLIB 07 00
MAJ 0050 WAR 05/16/06 14:33 System Start Up none 00 00
MIN 0002 REC 05/16/06 14:33 PKG Installation PRT 02 00
MAJ 0014 ERR 05/16/06 14:33 NTCPU-LAN Link none 00 00
MAJ 0014 REC 05/16/06 14:35 NTCPU-LAN Link none 00 00
MIN 0002 ERR 05/16/06 14:36 PKG Installation CTP 08 00
MIN 0002 REC 05/16/06 14:37 PKG Installation VMS 08 00
MIN 0002 ERR 05/16/06 14:38 PKG Installation VMS 08 00
MIN 0002 REC 05/16/06 14:40 PKG Installation PRT 07 00
MIN 0002 ERR 05/16/06 14:40 PKG Installation PRT 07 00
MAJ 0006 ERR 05/16/06 14:41 Blocking ESIB 01 05
MAJ 0006 REC 05/16/06 15:01 Blocking ESIB 01 05
MAJ 0006 ERR 05/16/06 15:05 Blocking ESIB 01 07
MAJ 0006 REC 05/16/06 15:07 Blocking ESIB 01 07