UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1071
10-03-02 ETU Setup (DTI (T1) PKG Setup)
– T1 Signal Format Selection
Used to setup and confirm the
basic configuration data for logical
port number T1.
0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame)
(default = 1)
3
10-03-03 ETU Setup (DTI (T1) PKG Setup)
– Zero Code Suppression
Used to setup and confirm the
basic configuration data for the
Clear Channel Selection.
0 = B8ZS
1 = AMI/ZCS
(default = 0)
3
10-03-04 ETU Setup (DTI (T1) PKG Setup)
– Line Length Selection
Used to setup and confirm the
basic configuration data for the
Line Length Selection.
0 = 0 feet ~ 133 feet
1 = 133 feet ~ 266 feet
2 = 266 feet ~ 399 feet
3 = 399 feet ~ 533 feet
4 = 533 feet ~ 655 feet
(default = 0)
3
10-03-05 ETU Setup (DTI (T1) PKG Setup)
– T1 Clock Source
Used to setup and confirm the
basic configuration data for the DTI
trunk type assignment.
0 = Internal
1 = External
(default = 1)
3
10-03-06 ETU Setup (DTI (T1) PKG Setup)
– Number of Ports
Used to setup and confirm the
basic configuration data for the
number of ports required.
0 = Auto
1 = 4 Ports
2 = 8 Ports
3 = 12 Ports
4 = 16 Ports
5 = 20 Ports
(default = 0)
3
10-09-01 DTMF and Dial Tone Circuit
Setup
For ANI/DNIS, reserve at least one
DTMF receiver for DTMF reception
(entry 0 or 2).
Use the following as a guide when
allocating DTMF receivers:
In light traffic sites, allocate one
DTMF receiver for every 10
devices that use them.
In heavy traffic sites, allocate one
DTMF receiver for every five
devices that use them.
0 = Common Use
1 = Extension Only
2 = Trunk Only
Default:
Circuit/Resource 01~08 =
1 (Extensions)
Circuit/Resource 09~32 =
2 (Trunks)
Circuit/Resource 33~96 =
0 (Not Used)
Circuit/Resource 97~160
= 0 (Common)
When PZ-BS10 is
installed, 97~160 are
available
3
10-39-01 Fractional Setup – Fractional Use to enable (1) or disable (0) T1/
PRI fractional function.
0 = Disable
1 = Enable
(default = 0)
3
14-01-02 Basic Trunk Data Setup –
Transmit Level
Use to select transmit level of
CODEC Gain (signal amplification)
for each trunk.
Trunks 1~200
1~63
(-15.5 ~ +15.5dB in 0.5dB
intervals)
[default = 32 (0dB)]
3
14-01-03 Basic Trunk Data Setup –
Receive Level
Use to select receive level of
CODEC Gain (signal amplification)
for each trunk.
Trunks 1~200
1~63
(-15.5 ~ +15.5dB in 0.5dB
intervals)
[default = 32 (0dB)]
3