UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1133
15-07-01 Programmable Function Keys Assign function keys for trunk
group access (code 02 + group)
or Call Appearance (CAP) Keys
(code 08 + CAP Key orbit
0001~9999 (or 0000 for auto
assign).
Trunk Groups: 1~100
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3
20-02-02 System Options for Multiline
Telephones
– Trunk Group
Access Key Operating Mode
Set the operating mode of the
extension trunk group keys.
Operating Modes:
Incoming and Outgoing Access = 0
Outgoing Access = 1
Incoming Access = 2
0 = Outgoing / Incoming
1 = Outgoing
2 = Incoming
(default = 0)
3
20-29-01 Timer Class for Extension – Day/
Night Mode 1~8, Class Number
Assign the timer class to each
extension. There are 16 Classes
that can be assigned. You make
eight entries for this Program, one
for each Night Service Mode. This
entry includes virtual extension
numbers.
0~15
0 = Not assigned
(default = 0)
3
20-31-04 Timer Class Timer Assignment –
Intercom Interdigits Time
(Intercom I/D Timer)
When placing Intercom calls,
extension users must dial each digit
in this time.
0~64800 (seconds)
(default = 10 seconds)
3
21-01-02 System Options for Outgoing
Calls – Intercom Interdigit Time
When placing Intercom calls,
extension users must dial each digit
in this time.
0~64800 (seconds)
(default = 10 seconds)
3
21-01-05 System Options for Outgoing
Calls – Disconnect Time When
Dial Tone Not Detected
If 14-02-11 is enabled, the system
skips over a trunk if dial tone is not
detected. This option pertains to
calls placed using Speed Dial,
ARS, Last Number Redial or Save
Number dialed. It does not pertain
to line key or Direct Trunk Access
calls.
0~64800 (seconds)
(default = 3 seconds)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3