Issue 1.0 UNIVERGE SV8100
2 - 1194 UNIVERGE Multimedia Conference Bridge
Related Features
None
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
10-09-01 DTMF and Dial Tone Circuit Setup Assign at least one circuit for DTMF
reception (type 0 or 1). Use the
following as a guide when
allocating DTMF receivers:
In light traffic sites, allocate one
DTMF receiver for every 10
devices that use them.
In heavy traffic sites, allocate
one DTMF receiver for every
five devices that use them.
0 = Common Use
1 = Extension Only
2 = Trunk Only
Default:
Circuit/Resource 01~08
= 1 (Extensions)
Circuit/Resource 09~32
= 2 (Trunks)
Circuit/Resource 33~96
= 0 (Not Used)
Circuit/Resource
97~160 = 0 (Common)
When PZ-BS10 is
installed, 97~160 are
available
3
10-55-01 Package Network Setup – IP
Address
Use to define the IP Address for the
CD-ETIA.
When the blade is deleted
from the system using
Program 90-05, the
programming for the slot in
10-55 is set back to default.
0.0.0.0 ~
126.255.255.254
128.0.0.1 ~
191.255255.254
192.0.0.1 ~
223.255.255.254
(default = 172.16.1.100)
3
10-55-03 Package Network Setup – Main/
Add-on
The Main setting is to be utilized to
distribute an IP Address to the
blade.
0 = Main
1 = Add-on
(default = 1)
3