UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1267
80-03-03 DTMF Tone Receiver Setup – Min.
detect level
Use to define the various minimum
detect levels for the DTMF Tone
Receiver.
0~15
detect level 0:
–10dBm(0) to
–25dBm(15)
detect level 1:
–15dBm(0) to
–30dBm(15)
detect level 2:
–20dBm(0) to
–35dBm(15)
detect level 3:
–25dBm(0) to
–40dBm(15)
detect level 4:
–30dBm(0) to
–45dBm(15)
detect level 5:
–35dBm(0) to
–50dBm(15)
detect level 6:
–40dBm(0) to
–55dBm(15)
detect level 7: -
45dBm(0) to -
60dBm(15)
detect level 8: -
50dBm(0) to -
65dBm(15)
detect level 9: -
55dBm(0) to -
70dBm(15)
detect level 10: -
60dBm(0) to -
75dBm(15)
detect level 11: -
65dBm(0) to -
80dBm(15)
detect level 12: -
70dBm(0) to -
85dBm(15)
detect level 13: -
75dBm(0) to -
90dBm(15)
detect level 14: -
80dBm(0) to -
95dBm(15)
detect level 15: -
85dBm(0) to -
100dBm(15) default:
Type 1 = 10 (-20dBm)
Type 2 = 15 (-25dBm)