UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 1305
20-13-01 Class of Service Options
(Supplementary Service) – Long
Conversation Alarm
Turns Off (0) or On (1) the Warning
Tone for Long Conversation (not for
single line telephones).
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-21-01 System Options for Long
Conversation – Long
Conversation Alarm 1
After a user places a trunk call, the
system sends the first warning tone
to their extension after this time
(0~64800 seconds).
0~64800 (seconds)
(default = 170)
3
20-21-02 System Options for Long
Conversation – Long
Conversation Alarm 2
After hearing the first warning tone,
the system sends additional
warning tones after this time
(0~64800 seconds). The warning
tones continue, spaced by this time,
until the user hangs up.
0~64800 (seconds)
(default = 180)
3
20-28-01 Trunk to Trunk Conversation –
Conversation Continue Code
Enter a single digit Continue Code
for the DISA call to use to
immediately disconnect or continue
their outside call (0~9, or
# are
accepted entries).
0~9, #,
(default not assigned)
3
20-28-02 Trunk to Trunk Conversation –
Conversation Disconnect Code
Enter a single digit Disconnect for
the DISA call to use to immediately
disconnect or continue their outside
call (0~9, or
# are accepted
entries).
0~9, #,
(default not assigned)
3
20-28-03 Trunk to Trunk Conversation –
Conversation Continue Time
When Program 14-01-25 is
enabled, determine the time a call is
extended when the user dials the
Continue code (defined in Program
20-28-01).
0~64800 (seconds)
(default = 0 seconds)
3
21-01-01 System Options for Outgoing
Calls – Seizure Trunk Line Mode
When a trunk is selected does it
select it based off the Trunk Route
Priority (0) or based off the trunk
that has not been used in the
longest time.
0 = Priority Route
1 = Circular Route
(default = 0)
3
21-01-03 System Options for Outgoing
Calls – Trunk Interdigit Time
(External)
The system waits for this time to
expire before placing the call in a
talk state (Call Timer starts after
time expires, Voice Over and Barge-
In are not allowed until after time
expires).
0~64800 (seconds)
(default = 5 seconds)
3
25-07-07 System Timers for VRS/DISA –
Long Conversation Warning Tone
Time
Determine the time the system
should wait before the Warning
Tone is heard by DISA callers
(0~64800 seconds). If an outside
call is transferred or forwarded
off-premise using an outside trunk,
this time starts immediately. This
occurs if either trunk involved in the
call is programmed for the Warning
Tone (Program 14-01-17).
0~64800 (seconds)
(default = 1800 seconds)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3