Issue 1.0 UNIVERGE SV8100
2 - 180 Call Forwarding/Do Not Disturb Override
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Operation
To override an extension Call Forwarding or Do Not Disturb:
1. Call the forwarded or DND extension.
2. Press the Override key (Program 15-07 or SC 751: 37).
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
11-12-01 Service Code Setup (for Service
Access) – Bypass Call
Customize the Service Code which
is to be used for Call Forwarding/
DND Override.
MLT, SLT
(default = 707)
3
11-16-06 Single Digit Service Code Setup
– DND/Call Forward Override
Bypass
Customize the 1-digit Service Code
used for DND/Call Forward
Override.
(default not assigned)
3
15-07-01 Programmable Function Keys Use to assign functions to multiline
terminal line keys.
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
extensions.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
20-13-04 Class of Service Options
(Supplementary Service) – Call
Forward/DND Override (Bypass
Call)
Turns On or Off the ability to use
Call Forwarding/DND Override.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3