EasyManua.ls Logo

NEC Univerge SV8100 - Page 208

NEC Univerge SV8100
1386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 1.0 UNIVERGE SV8100
2 - 184 Call Monitoring
Operation
The call must be set up for about 10 seconds before it can be Monitored. Listen for busy/ring or busy
tone.
To Call Monitor after calling a busy extension:
1. Call a busy extension.
2. Press the Barge-In key (Program 15-07 or SC 751: 34).
- OR -
The following steps are not available for DISA or Tie Line trunks.
1. Dial the extension number of the busy internal party.
2. Dial the single digit service code or the service code 710 (the access code will change).
20-13-32 Class of Service Options
(Supplementary Service) – Deny
Multiple Barge-Ins
In an extension Class of Service,
Allow (1) or Deny (0) the extension
ability to have multiple users Barge-
In to their conversation.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-45 Class of Service Options
(Supplementary Service) – MIC
Key Mode While Call Monitoring
Set per class of service, when in
Call Monitoring Mode determines if
the monitored parties receives the
barge in alert tone when Coaching
Mode is enabled.
0 = Enable
1 = Disable
(default = 1 for
COS 1~15)
3
20-14-11 Class of Service Options for
DISA/E&M – DISA/Tie Trunk
Barge-In
In an extension Class of Service,
Enable (1) or Disable (0) a DISA or
tie trunk user from using the Barge-
In feature.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-18-07 Service Tone Timers – Intrusion
Tone Repeat Time
After a user Barges In, the system
repeats the Barge-In tone after this
interval. Normally, you should
disable this time by entering 0. (This
time also affects any other type of
call interruption features, such as
Voice Mail Conversation Recording,
Voice Over, etc.)
0~64800 (seconds)
(default = 0 seconds)
3
21-01-03 System Options for Outgoing
Calls – Trunk Interdigit Time
(External)
Program how long an extension
must wait before using the Barge-In
feature can be used on a call (this
time expires before a call is put in a
talk state). This time also affects
Voice Over.
0~64800 (seconds)
(default = 5 seconds)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals