UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 301
Operation
To use Continued Dialing:
1. Place an intercom or trunk call.
2. Continue dialing after the call connects.
Toll Restriction and Class of Service programming may limit Continued Dialing.
20-13-13 Class of Service Options
(Supplementary Service) –
Continued Dialing (DTMF) Signal
on ICM Call
Turns Off (0) or On (1) the
extension ability to use Continued
Dialing, which allows DTMF signal
sending while talking on extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
21-04-01 Toll Restriction Class for
Extensions
Assign a Toll Restriction Class
(1~15) to an extension.
Day/Night Mode
1~9 (9 = Power Failure
Mode)
1~15
(default = 2)
3
21-05-04 Toll Restriction Class
Maximum Number of Digits Table
Assignment
Select the table (defined in Program
21-06-03) to be used to determine
the maximum number of digits
allowed for outgoing calls.
1~4 =Table
0 =Disable (None)
Default:
1, 2, 6~15 = 0
3 = 1
4 = 2
5 = 3
3
21-06-03 Toll Restriction Table Data Setup
– Maximum Number of Digits
Table Assignment
Set the Maximum Number of digits
dialed for each table.
4-30
default:
Tables 1~4 = 30
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3