Issue 1.0 UNIVERGE SV8100
2 - 378 Direct Inward Dialing (DID)
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
10-03-01 ETU Setup Use program 10-03-XX to setup and
confirm the basic configuration data
for each blade. This program
represents different data depending
on the blade installed in the slot.
Please refer the SV8100
Programming Manual for a more
detailed description of this program.
The assigned data varies
depending on the blade
installed in the slot.
Please refer to the
SV8100 Programming
Manual for a more
detailed description of
the 10-03-XX programs.
3
10-09-01 DTMF and Dial Tone Circuit
Setup
If the system has DTMF DID trunks,
be sure to reserve at least one circuit
for analog trunk DTMF reception
(type 0 or 2). There must be an
available receiver for each DTMF
DID trunk.
Use the following as a guide when
allocating DTMF receivers:
In light traffic sites, allocate one
DTMF receiver for every 10 devices
that use them.
In heavy traffic sites, allocate one
DTMF receiver for every five devices
that use them.
0 = Common Use
1 = Extension Only
2 = Trunk Only
Default:
Circuit/Resource 01~08
= 1 (Extensions)
Circuit/Resource 09~32
= 2 (Trunks)
Circuit/Resource 33~96
= 0 (Not Used)
Circuit/Resource 97~160
= 0 (Common)
When PZ-BS10 is
installed, 97~160 are
available.
3
14-05-01 Trunk Group – Trunk group
Number
Put DID trunks in the same trunk
group (other than group 1). If you
have several types of DID trunks, put
each type in a separate trunk group.
Trunks 1-200
Trunk Group 1-100
Priority 1-200
Default = All trunks in
Trunk Group 1 with
priority in trunk order.
Trunk 1 priority = 1 Trunk
200 priority = 200.
3
15-07-01 Programmable Function Keys You can assign line or Call
Appearance (CAP) Keys for DID
trunks (Trunks: 1~200).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3
20-06-01 Class of Service for
Extensions
Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port =
Class 1
3