20-13-10 Class of Service Options
(Supplementary Service) –
Barge-In Monitor
In an extension Class of Service,
enable the Barge-In Speech Mode
or Monitor Mode at the initiating
extension (i.e., Barge-In initiator).
0 = Speech
1 = Monitor
(default = 0 for
COS 1~15)
3
20-13-11 Class of Service Options
(Supplementary Service) – Room
Monitor, Initiating Extension
Turns Off or On an extension user
ability to Room Monitor other
extensions.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-12 Class of Service Options
(Supplementary Service) – Room
Monitor, Extension Being
Monitored
Turns Off or On an extension ability
to be monitored.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-13 Class of Service Options
(Supplementary Service) –
Continued Dialing (DTMF) Signal
on ICM Call
Turns Off or On the extension user
ability to use Continued Dialing,
which allows DTMF signal sending
while talking on extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-14 Class of Service Options
(Supplementary Service) –
Department Calling (PLT No
Called Extension)
Turns Off or On an extension user
ability to call a Department Group
Pilot.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-15 Class of Service Options
(Supplementary Service) –
Barge-In, Initiate
Turns Off or On an extension user
ability to barge-in on other's calls.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-16 Class of Service Options
(Supplementary Service) –
Barge-In, Receive
In an extension Class of Service,
turns Off or On Barge-In at the
receiving extension (i.e., Barge-In
receive).
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-17 Class of Service Options
(Supplementary Service) –
Barge-In Tone/Display (Intrusion
Tone)
In an extension Class of Service,
turns Off or On the Barge-In
(Intrusion) Tone. If disabled, this
also turns off the Barge-In display at
the called extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-18 Class of Service Options
(Supplementary Service) –
Programmable Function Key
Programming (General Level)
Turns Off or On an extension user
ability to program General function
keys using Service Code 751 (by
default). (Refer to Program 20-07-
10 for Service Code 752.)
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-19 Class of Service Options
(Supplementary Service) –
Selectable Display Messaging
(Text Messaging)
Turns Off or On an extension user
ability to use Selectable Display
Messaging.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-20 Class of Service Options
(Supplementary Service) –
Account Code/Toll Restriction
Operator Alert (Restricted
Operation Transfer)
Turns Off or On operator alert when
an extension improperly enters an
Account Code or violates Toll
Restriction.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3