EasyManua.ls Logo

NEC Univerge SV8100 - Page 560

NEC Univerge SV8100
1386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 1.0 UNIVERGE SV8100
2 - 536 Flexible Timeouts
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
20-01-08 System Options – Trunk Queuing
Callback Time
Set the Trunk Queuing callback
time. A Trunk Queuing Callback
rings an extension for this interval.
0~64800 (seconds)
(default = 15 seconds)
3
20-01-09 System Options – Callback/
Trunk Queuing Cancel Time
The system cancels an extension
Callback or Trunk Queueing
request after this interval.
0~64800 (seconds)
(default = 64800
seconds)
3
20-04-03 System Options for Virtual
Extensions – CAR/SIE/Virtual
Extension Delay Interval
CAR Keys/SIE Keys/Virtual
Extensions set for Delayed Ringing
(see Program 15-11) ring the
extension after this interval.
0~64800
(default = 10 seconds)
3
20-29-01 Timer Class for Extensions Assign the timer class (0~15) to
each extension for each Night
mode. This entry includes virtual
extension number.
0~15
0 = Not assigned
(default = 0)
3
20-30-01 Timer Class for Trunks Assign the timer class (0~15) to
each trunk for each Night mode.
0~15, #,
0 = Not assigned
(default = 0)
3
20-31-01 Timer Class Timer Assignment –
Trunk Queuing Callback
Duration Time
Trunk Queuing Callback rings an
extension for this time.
0~64800 (seconds)
(default = 15 seconds)
3
20-31-02 Timer Class Timer Assignment –
Callback / Trunk Queuing Cancel
Time
The system cancels an extension
Callback or Trunk Queueing
request after this time.
0~64800 (seconds)
(default = 64800
seconds)
3
20-31-03 Timer Class Timer Assignment –
CAR/SIE/Virtual Extension Delay
Interval
CAR Keys/SIE Keys/Virtual
Extensions set for Delayed Ringing
(refer to 15-11: Virtual Extension
Delayed Ring Assignment) ring the
extension after this interval.
0~64800 (seconds)
(default = 10 seconds)
3
20-31-04 Timer Class Timer Assignment –
Intercom Interdigits Time
(Intercom I/D Timer)
When placing Intercom calls,
extension users must dial each digit
within time.
0~64800 (seconds)
(default = 10 seconds)
3

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals