Issue 1.0 UNIVERGE SV8100
2 - 706 Meet Me Conference
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
For additional programming for Paging, refer to the Paging External and Paging Internal features.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
15-07-01 Programmable Function Keys Assign function keys for
Conference (code 07).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99
(Appearance Function
Code) (Service Code
752 by default)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port
= Class 1
3
20-10-06 Class of Service Options
(Answer Service) – Meet-Me
Conference and Paging
Turns Off (0) or On (1) an extension
to use Meet-Me Conference and
Paging.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
31-01-04 System Options for Internal/
External Paging – Privacy
Release Time
Set the Privacy Release Time.
After the user initiates Meet Me
Conference, the system waits this
interval for the Paged party to join
the conversation.
0~64800 (seconds)
(default = 90 seconds)
3