UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 759
80-03-06 DTMF Tone Receiver Setup –
Backwards Twist Level
Use this option to define the
backwards twist level for DTMF
Tone Receiver.
0~9
(1dB ~ 10dB)
default:
All Receivers =
3
80-03-07 DTMF Tone Receiver Setup – ON
Detect Time
Use this option to define the On
detection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
3
80-03-08 DTMF Tone Receiver Setup –
OFF Detect Time
Use this option to define the Off
detection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
3
80-04-01 Call Progress Tone Detector
Setup – Detection Level
Use to define the detection levels
for the Call Progress Tone
Detector.
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
3
80-04-02 Call Progress Tone Detector
Setup – Min. Detection Level
Use to define the minimum
detection levels for the Call
Progress Tone Detector.
0~15
detect level 0:
–15dBm(0) to
–30dBm(15)
detect level 1:
–30dBm(0) to
–45dBm(15)
detect level 2:
–40dBm(0) to
–55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
3
Program
Number
Program Name Description/Comments Assigned Data