Issue 1.0 UNIVERGE SV8100
2 - 764 Music on Hold
Music on Hold for non-DDI Trunk calls
The music on hold source is set per trunk port by Program 14-08
There are 3 options available:
0 – Use the music source set by Program 10-04-01
1 – Back Ground Music input.
2 – ACI input via a PGD(2) Unit.
The music source will be used for outgoing trunk calls or incoming non-DDI calls only.
Option Available for Using System Tone
The Music on Hold feature has been enhanced to allow callers to hear a system tone instead of playing the internal
or externa music.
Conditions
A maximum of 97 Music on Hold sources are possible; 96 from PGD(2)-U( ) ADP ports and
one from the side of the chassis.
External music on hold source for internal calls is only provided via audio input on the
CD-CP00-AU. Program 10-04-01 is to be set for 1 = External Source.
No music is provided to internal calls on hold via the ACI input.
Use the combination of Program 10-04, Program 10-21, Program 10-38 and Program 14-08.
The PGD(2)-U( ) ADP can connect to a CD-8DLCA, CD-16DLCA, or CD-LTA.
A maximum of 56 PGD(2)-U( ) ADP units can be installed in an UNIVERGE SV8100 system. Refer to the
UNIVERGE SV8100/SV8300 System Hardware Manual for more information.
Default Setting
Music on Hold is provided from the internal (synthesized) music source.
System Availability
Terminals
None
Required Component(s)
PGD(2)-U( ) ADP
ESIB(8)-U( ) ETU with ESIE(8)-U( ) fitted