Issue 1.0 UNIVERGE SV8100
2 - 806 (OPX) Off-Premise Extension
Refer to Single Line Telephones on page 2-933 for related programming.
Operation
Normal call handling procedures for single line telephones apply.
80-03-07 DTMF Tone Receiver Setup – ON
Detect Time
Use this option to define the On
detection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
3
80-03-08 DTMF Tone Receiver Setup –
OFF Detect Time
Use this option to define the Off
detection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
3
80-04-04 Call Progress Tone Detector
Setup – No Tone Time
Use to define the no tone time for
the Call Progress Tone Detector.
0~255 (30+30-7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
3
82-11-01 LCA Initial Setup – Bounce
Protect Time
Specify a time for detection of a
valid 0ff-Hook indication that is
long enough to prevent an
unintentional bounce of the
receiver from being detected as a
new Off-Hook indication from a
Single Line Telephone.
0 = No Setting
1~15 = 100ms~1.5sec
(default = 3)
3
82-11-02 LCA Initial Setup – HookFlash
Start Time
Specify the minimum hookflash
time from a Single Line Telephone
or analog Voice Mail system before
it is detected as the beginning of a
valid hookflash.
0 = 40ms
1~15 = 90ms~790ms
(default = 5)
3
82-11-03 LCA Initial Setup – HookFlash
End Time
Specify the maximum hookflash
duration from a Single Line
Telephone to receive a second dial
tone.
0 = HST+0ms 1~15 =
HST+100ms~HST+1500
ms
(HST=Hookflash Start
Time)
(default = 7)
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3