UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 809
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
10-05-01 General Purpose Relay Setup –
Slot No. Physical Port of DLC
Sensor Circuit No.
Define which relay circuits (5~8) on
the PGD(2)-U( ) ADP are used for
General Purpose Relays.
Slot No: 0~24
DCLA Port: 0~16
Relay No: 0, 5~8
After each entry,
pressing the
Transfer Key
advances to the
next entry.
(default = 0 - 0 - 0)
3
10-21-04 CD-CP00-AU Hardware Setup –
External Source I/O Selection on
CD-CP00-AU
Define what the I/O ports on the
CD-CP00-AU are used for.
0 = External MOH (CN8)/
External Speaker(CN9)
1 = BGM source (CN8)/
External Speaker(CN9)
2 = External MOH (CN8)/
BGM source (CN9)
Relations between
CN number and
Relay number are
as follows:
CN8 = Relay2
CN9 = Relay1
(default = 1)
3
11-12-50 Service Code Setup (For Service
Access) – General Purpose Relay
Specify the service code to be
used for toggling the relay open
and closed.
MLT, SLT
(default = 780)
3
15-07-01 Programmable Function Keys Assign function keys for External
Paging zones (19 + zone) and
External All Call Page (20). If
required, define a function key for a
multiline terminal to use the
general purpose relay (51).
Line Key 1~48
0~99 (Normal Function
Code 751 by default)
00 ~
99 (Appearance
Function Code) (Service
Code 752 by default)
3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15) to
an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port =
Class 1
3