EasyManua.ls Logo

NEC Univerge SV8100 - Page 869

NEC Univerge SV8100
1386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 845
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Operation
None
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
14-02-09 Analog Trunk Data Setup – Busy
Tone Detection
Use to set the basic options for
each analog trunk port.
0 = Disable
1 = Enable
(default = 1)
3
14-02-14 Analog Trunk Data Setup – Loop
Start/Ground Start
Use to set the basic options for
each analog trunk port.
0 = Loop Start (Loop)
1 = Ground Start
(Ground)
(default = 0)
3

Table of Contents

Other manuals for NEC Univerge SV8100

Related product manuals