UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 895
Guide to Feature Programming
The Level 1, Level 2 and Level 3 columns indicate the programs that are assigned when programming
this feature in the order they are most commonly used. These levels are used with PCPro and WebPro
wizards for feature programming.
Level 1 – these are the most commonly assigned programs for this feature.
Level 2 – these are the next most commonly assigned programs for this feature.
Level 3 – these programs are not often assigned and require an expert level working knowledge of
the system to be properly assigned.
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3
20-06-01 Class of Service for Extensions Assign a Class of Service (1~15)
to an extension.
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
Extension port 101 =
Class 15
All other extension port =
Class 1
3
20-08-01 Class of Service Options
(Outgoing Call Service) –
Intercom Calls
Turns Off or On Intercom calling
for the extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
21-01-09 System Options for Outgoing
Calls – Ringdown Extension
Timer (Hotline Start)
After the user lifts the handset, the
extension automatically calls the
ringdown destination after this
interval (0~64800 seconds). A
setting of 0 immediately rings the
programmed extension. Any other
setting delays the ringdown the
number of seconds programmed.
0~64800 seconds
(default = 0 seconds)
3
21-11-01 Extension Ringdown (Hotline)
Assignment
Program the ringdown (Hotline)
source and destination (target)
number, up to 24 digits (512
Hotline assignments). Remember
to include the trunk access code
(usually 0) in front of the number
when dialing outside numbers.
When programming Speed Dial –
System numbers as the
destination, the entry should be
753 + bin number (the service
code for Speed Dialing and the
Speed Dial bin number).
0, , #, Pause, Hook
Flash,
@ (Code to wait for
answer supervision)
(maximum 24 digits)
(default not assigned)
3