UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 939
80-03-04 DTMF Tone Receiver Setup – Max.
detect level
Use this option to define the
maximum detection level for DTMF
Tone Receiver.
0~15
detect level 0: 0dBm(0) to
–15dBm(15)
detect level 1:
–5dBm(0) to –20dBm(15)
detect level 2:
–10dBm(0) to –25dBm(15)
detect level 3:
–15dBm(0) to –30dBm(15)
detect level 4:
–20dBm(0) to –35dBm(15)
detect level 5:
–25dBm(0) to –40dBm(15)
detect level 6:
–30dBm(0) to –45dBm(15)
detect level 7: -35dBm(0) to
-50dBm(15)
detect level 8: -40dBm(0) to
-55dBm(15)
detect level 9: -45dBm(0) to
-60dBm(15)
detect level 10: -50dBm(0)
to -65dBm(15)
detect level 11: -55dBm(0)
to -70dBm(15)
detect level 12: -60dBm(0)
to -75dBm(15)
detect level 13: -65dBm(0)
to -80dBm(15)
detect level 14: -70dBm(0)
to -85dBm(15)
detect level 15: -75dBm(0)
to -90dBm(15)
default:
Type 1~5 = 0
3
80-03-05 DTMF Tone Receiver Setup –
Forward twist level
Use this option to define the forward
twist level for DTMF Tone Receiver.
0~9
(1dB ~ 10dB)
default:
All Receivers = 9
3
80-03-06 DTMF Tone Receiver Setup –
Backward twist level
Use this option to define the
backwards twist level for DTMF
Tone Receiver.
0~9
(1dB ~ 10dB)
default:
All Receivers = 9
3
80-03-07 DTMF Tone Receiver Setup – ON
detect time
Use this option to define the On
dectection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
3
80-03-08 DTMF Tone Receiver Setup – OFF
detect time
Use this option to define the Off
dectection time for DTMF Tone
Receiver.
1~255
(15+ 15 ms ~ 3825 ms)
default:
All Receivers = 1
3
Program
Number
Program Name Description/Comments Assigned Data
Level
1 2 3