UNIVERGE SV8100 Issue 1.0
SV8100 Features and Specifications Manual 2 - 951
20-13-06 Class of Service Options
(Supplementary Service) –
Automatic Off-Hook Signaling
(Automatic Override)
Allows a busy extension ability to
Manually (0) or Automatically (1)
receive Off-Hook signals.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-07 Class of Service Options
(Supplementary Service) –
Message Waiting
Turns Off (0) or On (1) an extension
ability to leave Message Waiting.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-08 Class of Service Options
(Supplementary Service) –
Conference
Turns Off or On an extension ability
to initiate a conference or Meet Me
Conference.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-09 Class of Service Options
(Supplementary Service) –
Privacy Release
Turns Off or On an extension ability
to initiate a Voice Call Conference.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-10 Class of Service Options
(Supplementary Service) – Barge-
In Monitor
In an extension Class of Service,
enable the Barge-In Speech Mode
(0) or Monitor Mode (1) at the
initiating extension (i.e., Barge-In
initiator).
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-11 Class of Service Options
(Supplementary Service) – Room
Monitor, Initiating Extension
Turns Off (0) or On (1) an extension
user ability to Room Monitor other
extensions.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-12 Class of Service Options
(Supplementary Service) – Room
Monitor, Extension Being
Monitored
Turns Off (0) or On (1) an extension
ability to be monitored.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-13 Class of Service Options
(Supplementary Service) –
Continued Dialing (DTMF) Signal
on ICM Call
Turns Off (0) or On (1) the
extension ability to use Continued
Dialing, which allows DTMF signal
sending while talking on extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-14 Class of Service Options
(Supplementary Service) –
Department Calling (PLT No
Called Extension)
Turns Off or On an extension user
ability to call a Department Group
Pilot.
0 = Off
1 = On
(default = 1 for
COS 1~15)
3
20-13-15 Class of Service Options
(Supplementary Service) – Barge-
In, Initiate
Turns Off (0) or On (1) an extension
user ability to barge-in on other's
calls.
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-16 Class of Service Options
(Supplementary Service) – Barge-
In, Receive
In an extension Class of Service,
turns On (1) or Off (0) Barge-In at
the receiving extension (i.e., Barge-
In receive).
0 = Off
1 = On
(default = 0 for
COS 1~15)
3
20-13-17 Class of Service Options
(Supplementary Service) – Barge-
In Tone/Display (Intrusion Tone)
In an extension Class of Service,
turns On (1) or Off (0) the Barge-In
(Intrusion) Tone. If disabled, this
also turns off the Barge-In display
at the called extension.
0 = Off
1 = On
(default = 1 for
COS 1~15)