Chapter 4 Standard Mode
4-76 NWA-033628-001 Rev.1.0
[Maintenance] Category
STEP3: Enter the unit number and slot number of blade from which you want to do the status display
on the [Status Display of Blade] screen, then click the [Read] button.
A blade status is displayed on the Status Display area with lamp indication.
No. Item Description
(7) Auto Update Time
Setting field
Select the Auto Update time.
Every 30 sec., Every 1 min. to Every 10 min.
(default: Every 30 sec.)
(8) Status Display Area View this area to confirm the status of specified blade with lamp indica-
tion. The following status display is available.
•Live LED
Blue (blink) : Normal operation
Blue (lit) : In setting up/In upgrading
Port occupation of each CKT No.
Black : The channel have not been occupied.
Red : The channel has been occupied.
Blue (blink) : No system data setting/etc.
Red (blink) : Make busy
Lamp Indications (Alarm)
Red (blink) : Alarm On
Black : Alarm Off
Lamp Indications (Information)
Green (blink): D channel link On
Black : D channel link Off/etc.