Chapter 4 Standard Mode
4-68 NWA-033628-001 Rev.1.0
[Tools] Category
Create a Script File
There are three ways to create a script file as described below. Here, method 1 is highlighted.
1. Write a system data script in Microsoft Excel and convert it to a CSV file (using the [Open] ( )
button).
2. Enter a system data script directly in the Script Entry Area (using the [New] ( ) button).
3. Read system data from the SV8300 to the Script Entry Area and edit it (using the [Read] button).
STEP1: Launch Microsoft Excel.
STEP2: Specify Columns A to E in an Excel sheet and click [Format (O)] > [Cell (E)] to set the dis-
play format a character string.
Delete Excel sheets 2 and 3.
STEP3: Fill out the Excel sheet with the command code, first data and second data as system data,
left-justified, to create an Excel file.
Sample setting: Set station numbers 3000, 3001 and 3002 for the IP Multiline Terminal.
No. Item Description
(10) [Apply] button Click to apply the contents of the script shown in the screen
as system data on the SV8300.
Command code
First data
Second data
You may enter a comment
in column E.