STEP1: Using CAT or PCPro (RS-232C connection), set the following system data on the SV8300:
•CM08
First data : 909
Second data : 0 (To use)
CM40 YY=10
First data : 1
Second data : X - XXXXXXXX (Station number)
CM13 YY=07
First data : X - XXXXXXXX (Station number)
Second data : 0 (Data station)
CM13 YY=18
First data : X - XXXXXXXX (Station number)
Second data : 0 (To send)
CM15 YYY=044
First data : 00 - 15 (Service control class A)
Second data : 0 (Restricted)