Chapter 2 Setting Up PCPro
2-10 NWA-033628-001 Rev.1.0
Connecting PCPro to the SV8300
Modem Connection
Hardware requirements
* Customer purchases
Connection method
STEP1: Using CAT or PCPro (RS-232C connection), set the following system data on the SV8300:
•CM08
First data : 909
Second data : 0 (To use)
• CM40 YY=10
First data : 1
Second data : X - XXXXXXXX (Station number)
• CM13 YY=07
First data : X - XXXXXXXX (Station number)
Second data : 0 (Data station)
• CM13 YY=18
First data : X - XXXXXXXX (Station number)
Second data : 0 (To send)
• CM15 YYY=044
First data : 00 - 15 (Service control class A)
Second data : 0 (Restricted)
Description Quantity Remarks
Required for the SV8300 COT blade 1 • Used to interface the SV8300 to a
public network.
Required for the remote
unit
PC* 1 unit • For the specifications of the PC
required, see “Operating Environ-
ments and Conditions”. Page 1-3
Modem* 1 unit • Modem supporting AT commands
• 28.8 Kbps or faster modem recom-
mended
RS-232C
straight cable
1 • Used to connect the modem and PC to
each other.