Chapter 4 Standard Mode
4-7 NWA-033628-001 Rev.1.0
[Implement] Category
System Data All Clear (CM00/CMEC)
Execute System Data All Clear on the SV8300 in the following steps:
STEP1: Click the [1] button [Quick Setup] screen.
The [1. All-Clear of System Data] screen is displayed in the work window.
STEP2: Set the [SENSE] switch to “E” on the CPU blade mounted in the SV8300.
STEP3: Press the [RESET] button on the CPU blade to reset.
Press the CPU blade [RESET] button and the lamps will change in their states as described
below.
STEP4: Check that the SV8300 has restarted.
Check that the RUN lump on the CPU blade indicates a normal operating state.
STEP5: Reconnect the communication link with the SV8300
Clear the communication link: click [System] > [Disconnect] ( Page 2-15 ), then estab-
lish the link: click [System] > [Connect] ( Page 2-12 ).
Change
Lamp states
RUN SYSD SI
Press the [RESET]
button
Off Off Off
Blinking blue fast Off Blinking green fast
Blinking blue fast Blinking red fast Off
Normal state Blinking blue
slowly
Off Off